Skip to main content

Trinity College Dublin, The University of Dublin

Menu Search



You are here Research > Research Groups > Nanobio - Nanomechanics Group

Publications

Papers from the Nanomechanics Team

Google Scholar: Martin Hegner

2016

Padovani, F., Duffi, J., Hegner, M. (2016) Microrheological Coagulation Assay Exploiting Micromechanical Resonators Analytical Chemistry 10.1021/acs.analchem.6b03347 pdf Mircrorheologial Clinical Assay for Blood Anomalies
Download PDF

Jadhav, V.S., Brüggemann, D., Wruck, F., Hegner, M. (2016) Single-molecule mechanics of protein-labelled DNA handles Beilstein J. Nanotechnol. 7, 138–148. DOI:10.3762/bjnano.7.16
Modified DNA handles for single molecule experiments
Download PDF

2015

Sinead Winters, Nina C. Berner, Rohit Mishra, Kim C. Dumbgen,Claudia Backes, Martin Hegner, Andreas Hirsch and Georg S. Duesberg (2015) On-surface derivatisation of aromatic molecules on graphene: the importance of packing density ChemComm 51, 16778, DOI: 10.1039/c5cc06433c
Chemical functionalisation of graphene interfaces
Download PDF

Walther, M.,Fleming, P.M., Padovani, F., Hegner, M. (2015) An optimized measurement chamber for cantilever array measurements in liquid incorporating an automated sample handling system EPJ Techniques and Instrumentation 2:7, DOI 10.1140/epjti/s40485-015-0017-7 Movie of liquid exchange in cantilever array measurement chamber
A detailed description of our latest analytical cantilever array sensing device. Fluidics, differential read-out and sample analysis
Download PDF

2014

Maloney, N., Lukacs, G., Jensen, J. Hegner, M. (2014) Nanomechanical Sensors for Single microbial cell growth monitoring Nanoscale 6, 8242-8249, DOI: 10.1039/C4NR01610F
Mechanical testing of single cells in real-time
Download PDF

Mishra, R., Hegner, M. (2014) Effect of non-specific species competition from total RNA on the static mode hybridization response of nanomechanical assays of oligonucleotides Nanotechnology 25, 225501
Detecting short nucleic acids in a coplex total RNA background
Download PDF

Maloney, N., Lukacs, G., Ball,S. L., Hegner, M. (2014) Device for filamentous fungi growth monitoring using the multimodal frequency response of cantilevers Rev. Sci. Instrum. 85, 015003; http://dx.doi.org/10.1063/1.4854655.
Growth monitoring of microfungi on nanomechanical sensors
Download PDF

2013

Jensen, J., Maloney, N., Hegner, M. (2013) A multi-mode platform for cantilever arrays operated in liquid Sensors and Actuators B: Chemical 183, 388–394 Link
Download PDF

2012

Hegner, M., Bruggemann, D., Skoko, D. (2012) Optical Tweezers, Encyclopedia of Nanotechnology, Bhushan, Bharat (Ed.), Springer, ISBN 978-90-481-9750-7, pages 1981 - 1991.
Download PDF

Lukacs, G. Maloney, N. and Hegner, M. (2012) Ink-Jet Printing: Perfect Tool for Cantilever Array Sensor Preparation for Microbial Growth Detection Journal of Sensors Vol 2012, Article ID 561256, 7 pages doi:10.1155/2012/561256.
Automation of cantilever functionalization with cells
Download PDF

Daly, R., Kumar, S., Lukacs, G., Lee, K., Weidlich, A., Hegner, M., Duesberg, G.S. (2012) Cell Proliferation Tracking Using Graphene Sensor Arrays Journal of Sensors, Article ID 219485, 7 pages doi:10.1155/2012/219485.
Graphene arrays for bioanalytical analysis
Download PDF

Noy, P., Steiner, R., Voelkle, J., Hegner, M. and Fattinger, Ch. (2012) Instrument for Label-Free Detection of Noncoding RNAs Journal of Sensors, Article ID 208079, 5 pages
doi:10.1155/2012/208079.
Continous flow nanomechanical measurements in Industry
Download PDF

Jensen, J., Farina, M., Zuccheri, G., Grange, W. and Hegner, M. (2012) Quantitative, Label-Free Detection of the Aggregation of α-Synuclein Using Microcantilever Arrays Operated in a Liquid Environment Journal of Sensors Vol. 2012 (2012), Article ID 874086, 7 pages doi:10.1155/2012/874086.
Protein aggregation as a cause for neurodegenerative diseases
Download PDF

Mishra, R., Grange, W. and Hegner, M. (2012) Rapid and Reliable Calibration of Laser Beam Deflection System for Microcantilever-Based Sensor Setups Journal of Sensors
Vol. 2012 Article ID 617386, 6 pages, doi:10.1155/2012/617386.
Geometrical differences require precise calibration of individual devices
Download PDF

Maloney, N., Lukacs, G., Nugaeva, N., Grange, W., Ramseyer, J. P., Jensen, J., Hegner, M. (2012) Fibre Optic Readout of Microcantilever Arrays for Fast Microorganism Growth Detection," J. of Sensors, vol. 2012, Article ID 405281, 6 pages. doi:10.1155/2012/405281.
Rapid microfungus growth analyis using nanomechanical sensors
Download PDF

Jensen, J. and Hegner, M. (2012) Predictions of the Compressible Fluid Model and its Comparison to Experimental Measurements of Q Factors and Flexural Resonance Frequencies for Microcantilevers J. of Sensors, vol. 2012, Article ID 258381, 7 pages. doi:10.1155/2012/258381.
Inverse behaviour of Quality factors observed in higher modes in the gas phase
Download PDF

2011 - 2008

2011

  • Park, K. K., Lee, H., Kupnik, M., Oralkan, O., Ramseyer, J. P., Lang, H. P., Hegner, M., Gerber, C., Khuri-Yakub, B. T. (2011) Capacitive micromachined ultrasonic transducer (CMUT) as a chemical sensor for DMMP detection Sensors and Actuators B-Chemical 160, 1120-1127. pdf
    Chemical sensing at the limit of 56 ppb of DMMP (Sarin alanog) by CMUT chemical sensor
  • Katranidis, A., Grange, W., Schlesinger, R.,Choli-Papadopoulou, T., Bruggemann, D., Hegner, M., Buldt, G. (2011) Force measurements of the disruption of the nascent polypeptide chain from the ribosome by optical tweezers FEBS Letters, 585, 1859–1863. pdf, supplemental video
    Using optical forces the molecular strength of the nascent polypeptide chain anchored in the ribosome machinery are determined

2010

  • Springer Handbook of Nanotechnology. Chapter: 'Nanomechanical Cantilever Array Sensors' Hans Peter Lang, Martin Hegner, Christoph Gerber Pages 427-452; ISBN: 978-3-642-02524-2 (Print)
  • Haas, P.,Then, P., Wild, A., Grange, W., Zorman, S., Hegner, M., Calame, M., Aebi, U., Flammer, J., Hecht, B. (2010) Fast Quantitative Single-Molecule Detection at Ultra low Concentrations Analytical Chemistry, 82, 14, 6299-6302. pdf - Supplemental information
    New fibre optical diagnostic method to screen for rare targets in a liquid environment

2009

  • Braun, T., Ghatkesar, M.K., Backmann, N. Grange, W., Boulanger, P., Letellier, L., Lang, H.P., Bietsch, A., Gerber, C., Hegner, M. (2009) Quantitative time-resolved measurement of membrane protein-ligand interactions using microcantilever array sensors Nature Nanotech. 4, 179-185. (doi:10.1038/NNANO.2008.398 ) pdf ; supplemental Information Development of a new quantitative virus biosensor. Nanomechanical silicon sensors functionalized with biomembranes detects specifically the presence of virus in liquid environments within minutes.

2008

  • Ghatkesar, M. K., Lang, H. P., Gerber, C., Hegner, M., Braun, T. (2008) Comprehenisive characterization of molecular interactions based on nanomechanics PLoS ONE, 2008;3(11):e3610. pdf Online tracking of pore formation in lipid vesicles - Combined mode - qualitative and quantitative readout
  • Ghatkesar, M. K., Rakhmatullina, E., Lang, H. P., Gerber, Ch., Hegner, M., Braun, T. (2008) Multi-parameter microcantilever sensor for comprehensive characterization of Newtonian fluids Sens. Actuators B:Chemical, 135,133-138. pdf Micro-rheological measurements using oscillating nanomechanical sensors
  • Huber, F., Lang, H. P., Hegner, M., Despont, M., Drechsler, U., Gerber, Ch. (2008) Analyzing refractive index changes and differential bending in microcantilever arrays Rev. Sci. Instr. 79, 086110. pdf Assessment of liquid contributions to optically readout nanomechanical signals
  • Grange, W., Haas, P., Wild, A., Lieb, M.A., Calame, M., Hegner, M., Hecht, B. (2008) Detection of transient events in the presence of background noise J. Phys. Chem. B 112 (23) 7140-7144. pdf Single molecule detection using optical fibres in a turbulent flow
  • Grange, W., Duckely, M., Husale, S., Jacob,S., Engel, A. and Hegner, M. (2008) VirE2: A Unique ssDNA Compacting Molecular Machine PLoS Biol 6(2) 343-351: pdf additional Supplemental Information Bacterial infection in plants. Genetic molecules which transfer into cellular compartment are spooled through the membrane by powerful molecular motor. Optical tweezers assay reveals forces involved in the process
  • Husale, S., Grange,W., Karle, M.,Bürgi, S., Hegner, M. (2008) Interaction of cationic surfactants with DNA: a single-molecule study Nucleic Acids Res., 36 (5), 1443-1449. pdf Optical tweezers experiment describing nanomechanical effect of charged molecules on single DNA molecules. Comparable molecules are applied in gene therapy for the translocation of DNA into cells
  • Ghatkesar, M.K., Braun, T., Barwich, V., Ramseyer, J.P., Gerber, C., Hegner, M., Lang, H.P. (2008) Resonating modes of vibrating microcantilevers in liquid Appl. Phys. Lett. 92(4), 043106. pdf Higher mode oscillation of micro cantilevers in liquids environment provide pg/Hz resolution

2007 - 2000

2007

  • Ghatkesar, MK; Barwich, V; Braun, T, Ramseyer, J.P., Gerber, C., Hegner, M., Lang, H.P., Drechsler, U., Despont, M. (2007) Higher modes of vibration increase mass sensitivity in nanomechanical microcantilevers Nanotechnology 18, 445502. pdf
  • Braun, T., Huber, F., Ghatkesar, M.K., Backmann, N., Lang, H.P., Gerber, C., Hegner, M. (2007) Processing of kinetic microarray signals Sens. Act. B -Chemical, 128, 75-82. pdf
  • Braun,T., Ghatkesar,M K., Barwich,V., Backmann, N., Huber, F., Grange, W.,Nugaeva, N., Lang, H. P., Ramseyer,J P., Gerber, Ch. and Hegner, M . (2007) Digital processing of multi-mode nano-mechanical cantilever data J. Phys.: Conf. Ser. 61, 341, doi:10.1088/1742-6596/61/1/069. pdf
  • Park, K.K., Lee, H,J.,Yaralioglu, G.G., Ergun, A.S., Oralkan, O., Kupnik, M., Quate, C.F., Khuri-Yakub, B.T., Braun, T., Ramseyer, J.P., Lang, H.P., Hegner, M., Gerber, Ch., Gimzewski, J.K. (2007) Capacitive micromachined ultrasonic transducers for chemical detection in nitrogen Appl. Phys. Lett. 91, 094102. pdf
  • Gerber, Ch. Hegner, M., Meyer, E. Special issue featuring papers from ICN&T 2006 Nanotechnology, ,18, 040201. pdf
  • Huber, F., Backmann, N., Grange, W., Hegner, M., Gerber, Ch. and Lang, H.P. (2007) Analyzing Gene Expression Using Combined Nanomechanical Cantilever Sensors J. Phys.: Conf. Ser. 61 450 doi:10.1088/1742-6596/61/1/090. pdf
  • Lang, H.P., Ramseyer, J.P., Grange, W., Braun, T., Schmid, D., Hunziker, P., Jung, C., Hegner, M.. and Gerber, Ch. (2007) An artificial nose based on microcantilever array sensors J. Phys.: Conf. Ser. 61 663 doi:10.1088/1742-6596/61/1/133, pdf
  • Dorrestijn, M., Bietsch, A., Açikalin, T., Raman, A., Hegner, M., Meyer, E.* and Ch. Gerber (2007) Chladni Figures Revisited based on Nanomechanics Phys. Rev. Lett. 98, 026102. pdf
  • Watari, M., Galbraith, J. Lang, H.P., Sousa, M., Hegner, M., Gerber, Ch., Horton, M.A. and McKendry, R.A.* (2007) Investigating the Molecular Mechanisms of In-plane Mechanochemistry on Cantilever Arrays J. Am. Chem. Soc. 129, 601-609. pdf ; pdf_supportfile
  • Nugaeva, N., Gfeller, K., Backmann, N., Lang, H.P., Guntherodt, H.J., Hegner, M.(2007) An antibody-sensitized microfabricated cantilever for the growth detection of Aspergillus niger spores Microscopy and Microanalysis, 13,13-17. pdf

2006

  • Zhang, J., Lang, H. P., Bietsch, A., Huber, F., Certa, U., Guntherodt, H.-J., Hegner, M.* Gerber, Ch. (2006) Rapid and label-free nanomechanical detection of biomarker transcripts in human RNA Nature Nanotechnology, 1 ,214-220. pdf
  • Braun, T., Backmann, N., Bietsch, A., Engel, A., Lang, H.P., Gerber, Ch., Hegner, M.* (2006) Conformational change of bacteriorhodopsin quantitatively monitored by microcantilever sensors Biophys. J., 90, 2970-2977. pdf
  • H.P. Lang*, Hegner M. and Gerber Ch. (2006) Microfabricated Cantilever Array Sensors for (Bio-) Chemical Detection in: Applied Scanning Probe Methods IV - Industrial Applications, B. Bhushan, H. Fuchs (Eds.), Springer Verlag (Berlin, New York, Heidelberg), Ch. 28, pp. 183-213. pdf
  • H.P. Lang*, Hegner M. and Gerber Ch. (2006) Nanomechanical Cantilever Array Sensors, in: Springer Handbook of Nanotechnology, 2nd edition, Springer Verlag (Berlin, New York, Heidelberg), Ch. 16, pp. 443-450. pdf

2005

  • Huber, F., Hegner, M., Gerber, Ch.,Guntherodt, H.J., Lang, H.P.* (2005) Label free analysis of transcription factors using microcantilever arrays Biosens. Bioelectron. 21 (8) 1599 - 1605. pdf
  • Lang, H.P.*, Hegner, M., Gerber, Ch. (2005) Cantilever array sensors Materials today 8, 30-36. pdf
  • Gfeller, K.Y, Nugaeva, N., Hegner, M.* (2005) Rapid biosensor for the detection of selective growth of Escherichia coli Appl. Env. Microbiol. 71 (5): 2626-2631. pdf
  • Bertoncini, P.*, Schoenauer, R., Agarkova, I., Hegner, M., Perriard, J.-C., Guntherodt, H.-J. (2005) Study of the Mechanical Properties of Myomesin Proteins Using Dynamic Force SpectroscopyJ. Mol. Biol. 348 (5): 1127-1137. pdf
  • Schoenauer, R., Bertoncini, P., Machaidze, G., Aebi, U., Perriard, J.C.*, Hegner, M.*, Agarkova, I. (2005) Myomesin is a molecular spring with adaptable elasticity J. Mol. Biol. 49 (2): 367-379. pdf
  • Gfeller, K., Nugaeva, N., Hegner, M.* (2005) Micromechanical oscillators as rapid biosensors for the detection of active growth of Escherichia coli Biosens. Bioelectron. 21(3) 528-533. pdf
  • Shahgaldian P.*, Pieles U, Hegner M. (2005) Enantioselective recognition of phenylalanine by a chiral amphiphilic macrocycle at the air-water interface: A copper-mediated mechanism Langmuir 21 (14): 6503-6507. pdf
  • Shahgaldian, P.*, Hegner, M., Pieles, U. (2005) A cyclodextrin Self-Assembled Monolayer (SAM) based surface plasmon resonance (SPR) sensor for enantioselective analysis of thyroxine J. Incl. Phenom. 53, 35-39. pdf
  • Braun, T., Barwich, V., Ghatkesar, M.K., Bredekamp, A.H., Gerber, Ch., Hegner, M.*, Lang, H.P.* (2005) Mass sensors for biomolecular detection in physiological environment Phys. Rev. E, 72, 031907, 1-9. pdf
  • Backmann, N., , Zahnd, Ch., Huber, F., Bietsch, A., Pluckthun, A., Lang, H.P., Guntherodt, H.J., Hegner, M.*, Gerber, Ch. (2005) A label-free immunosensor array using single-chain antibody fragments Proc. Natl. Acad. Sci. USA, 102 (41),14587-14592. pdf
  • Nugaeva, N., Gfeller, K.Y., Backmann, N., Lang, H.P., Düggelin, M., Hegner, M. (2005) Nanomechanical cantilever array sensors for selective fungal immobilization and real-time growth detection Biosens. Bioelectron. 21, 849-856. pdf

2004

  • Engel, A. & Hegner, M.* (2004). Atomic Force Microscopy & Laser Tweezers. Physics meets Biology, in: Matter and Materials (Gompper, G., Kaupp, U.B., Dhont, J.K.G., Richter, D. Winkler, R.G., Ed.), 19, Forschungszentrum Jülich, Jülich
  • Schwarzenbach, M.S.*, Reimann, P., Thommen, V., Hegner, M., Mumenthaler, M., Schwob, J., Guntherodt, H.J. (2004) Topological structure and chemical composition of inner surfaces of borosilicate vials PDA J. Pharm. Sci. Technol. 58 (3)169-175. pdf
  • Bietsch, A.*, Hegner, M., Lang, H.P., Gerber, C. (2004) Inkjet deposition of alkanethiolate monolayers and DNA oligonucleotides on gold: Evaluation of spot uniformity by wet etching Langmuir 20 (12): 5119-5122. pdf
  • Bietsch, A.*, Zhang, J.Y., Hegner, M., Lang, H.P., Gerber, Ch.(2004) Rapid functionalization of cantilever array sensors by inkjet printing Nanotechnology 15 (8): 873-880. pdf
  • Hegner, M.* (2004) The Basel NanoBio-Network Chimia 58, 788 - 791. pdf
  • Ghatkesar M. K., Barwich, V., Braun, T., Bredekamp, A.H., Drechsler, U., Despont, M., Lang, H. P., Hegner, M.*, Gerber Ch. (2004) RealTime Mass Sensing by Nanomechanical Resonators in Fluid Proc. IEEE Sensors 2004 1060 – 1063. pdf

2003

  • Hegner, M. * and Grange, W. (2003) Mechanics and imaging of single DNA molecules. J. Muscl. Res. Cell Mot. 23,367-375. pdf
  • Arntz, Y., Seelig, J.E., Zhang, J., Lang, H.P., Hunziker, P., Ramseyer, J.P., Meyer, E., Hegner, M.*, and Gerber, Ch. (2003) A label-free protein assay based on a nanomechanical cantilever array Nanotechnology 14, 86-90. pdf
  • Hegner, M.* and Arntz, Y. (2003) Advanced Biosensing Using Micromechanical Cantilever Arrays Methods in Molecular Biology 24, 39-49. pdf
  • Hegner, M.*, Grange, W. and Bertoncini, P. (2003) Measurement of Single Molecular Interactions by Dynamic Force Microscopy Methods in Molecular Biology 24, 369-382. pdf
  • Hegner, M.*, Gerber, Ch., Arntz, Y., Zhang, J., Bertoncini, P., Husale, S., Lang, H.P. and Grange, W. (2003) Biological Single Molecule Applications and Advanced Biosensing J. Chrom. Lib. 68, 241 - 263. in Emerging Technologies in Protein and Genomic Material Analysis (G.A. Marko-Varga, P.L. Orozlan Eds.) pdf

2002

  • Schumakovitch, I., Grange, W., Strunz, T., Bertoncini, P., Guntherodt, H.-J. and Hegner M.* (2002) Temperature Dependence of Unbinding Forces between Complementary DNA Strands Biophys J. 82, 517-521. pdf
  • Schwarzenbach, M.S., Reimann, P., Thommen, V., Hegner, M., Mumenthaler, M., Schwob, J., Guntherodt, H.J. * (2002) Interferon alpha-2a interactions on glass vial surfaces measured by atomic force microscopy PDA J. Pharm. Sci. Technol. 56, 78-89. pdf
  • Grange, W., Husale, S., Guntherodt, H.-J. and Hegner, M. * (2002) Optical tweezers system measuring the change in light momentum flux Rev. Sci. Instr. 73, 2308 2316. pdf
  • Husale, S., Grange, W. and Hegner, M. * (2002) DNA Mechanics Affected by Small DNA Interacting Ligands Single Mol. 3 ,(2-3), 91-96. pdf
  • McKendry, R., Zhang, J., Arntz, Y., Strunz, T., Hegner, M., Lang, H.P. *, Baller, M.K., Certa, C., Meyer, E., Güntherodt, H.-J. and Gerber, C. (2002) Multiple label-free biodetection and quantitative DNA-binding assays on a nanomechanical cantilever array Proc. Natl. Acad. Sci. USA 99 (15), 9783–9788. pdf
  • Hegner M.* (2002) Optics - The light fantastic Nature 419 (6903): 126-127. pdf
  • Lang, H.P. *, Hegner, M., Meyer, E and Gerber, C. (2002) Nanomechanics from atomic resolution to molecular recognition based on atomic force microscopy technology Nanotechnology 13, R29-R36. pdf
  • Hegner, M. * and Engel, A. (2002) Single Molecule Imaging and Manipulation Chimia 56, 506 - 514. pdf
  • Lang, H.P. *, Hegner, M., Gerber, C. (2002) Nanomechanics - The Link to Biology and Chemistry Chimia 56, 515 - 519. pdf

2001

  • Hegner M. * and Guntherodt, H.-J. (2001) Nanometer Scale Science and Technology - The impact of STM and AFM International School of Physics Enrico Fermi Volume 144, 1-40. pdf
  • Grange W., Strunz T., Schumakovitch I., Guntherodt, H.-J. and Hegner, M. * (2001) Molecular Recognition and Adhesion of Individual DNA Strands Studied by Dynamic Force Microscopy Single Mol. 2 (2), 75-78. pdf

2000

  • Hegner, M. * (2000) DNA Handles for Single Molecule Experiments Single Mol. 1 (2) 139-144. pdf
  • Strunz, T., Oroszlan, K., Schumakovitch, I., Guntherodt, H.-J. and Hegner M.* (2000) Model energy landscapes and the force-induced dissociation of ligand-receptor bonds Biophys. J. 79, 1206-1212. pdf
  • De Paris, R., Strunz, T., Oroszlan, K., Guntherodt, H.-J. and Hegner, M. * (2000) Force Spectroscopy and Dynamics of the Biotin-Avidin Bond Studied by Scanning Force Microscopy Single Mol. 1 (4) 285-290. pdf

1999 - 1992

1999

  • DHegner, M., Smith, S.B. and Bustamante, C. * (1999) Polymerization and mechanical properties of single RecA-DNA filaments Proc. Natl. Acad. Sci. USA 96 (18), 10109-10114. pdf

1998

  • Degner, M.* and Wagner, P. (1998) Ultraflat Au surfaces (TSG) for biological SPM applications, in: Procedures in Scanning Probe Microscopy, ed. Colton et al., Wiley & Sons Ltd. New York, 172-175. pdf
  • Wagner, P. * and Hegner, M. (1998) A general method for immobilizing biomolecules on gold for SPM in aqueous buffers, in: Procedures in Scanning Probe Microscopy, ed. Colton et al., Wiley & Sons Ltd. New York, 481-487. pdf

1996

  • Hegner, M. *, Dreier, M., Wagner, P., Semenza, G. and Guntherodt, H.-J. (1996) Modified DNA immobilized on bioreactive self-assembled monolayer on gold for dynamic force microscopy imaging in aqueous buffer solution J. Vac. Sci. Technol. B, 14, 1418-1421. pdf
  • Dammer, U., Hegner, M. *, Anselmetti, D., Wagner, P., Dreier, M., Huber, W. and Guntherodt, H.J. (1996) Specific Antigen/Antibody interactions measured by Force Microscopy Biophys. J., 70, 2437-2441. pdf
  • Wagner, P. *, Kernen, P., Zaugg, F., Hegner, M. and Semenza, G. (1996) omega-Functionalized self-assembled monolayers chemisorbed on ultraflat Au(111) surfaces for biological scanning probe microscopy in aqueous buffers J. Vac. Sci. Technol. B, 14, 1466-1471. pdf
  • Wagner, P., Hegner, M., Kernen, P., Zaugg, F. and Semenza, G.* (1996) N-hydroxysuccinimide ester functionalized self-assembled monolayers for covalent immobilization of biomolecules on gold Biophys. J., 70, 2052-2066. pdf
  • Weigert, S. *, Dreier, M. and Hegner, M. (1996) Frequency shifts of cantilevers vibrating in various media Appl. Phys. Lett. 69, 2834-2836. pdf

1995

  • Dammer, U., Anselmetti, D., Dreier, M., Hegner, M., Huber, W., Hurst, J., Misevic, G.N. and Guntherodt, H.J. * (1995) Measuring molecular adhesion with force microscopy Forces in SPM, NATO-ASI Serie E, Vol. 286, 625-632.
  • Wagner, P., Hegner, M., Guntherodt, H.-J. and Semenza, G.* (1995) Formation and in-situ modification of monolayers chemisorbed on template-stripped gold surfaces for operations on nano-scale Langmuir,11, 3867-3875. pdf
  • Dammer, U., Popescu, O., Wagner, P., Anselmetti, D., Guntherodt, H.J., Misevic, G.N. (1995 ) Binding strength between cell adhesion proteoglycans measured by atomic force microscopy Science 267(5201):1173-5.

1994

  • Shelden, R.A. *, Meier, L.P., Caseri, W.R., Suter, U.W., Hermann, R., Muller, M., Hegner, M. and Wagner, P. (1994) Nanophase molecular droplets: individual polystyrene molecules on mica imaged with scanning electron and atomic-force microscopy Polymer, 35, 1571-1575. pdf
  • Wagner, P., Kernen, P., Hegner, M., Ungewickell, E. and Semenza, G. * (1994) Covalent anchoring of proteins onto gold-directed NHS-terminated self-assembled monolayers in aqueous buffers: SFM imaging of Clathrin and its cages FEBS Letters, 356, 267-271. pdf
  • Dammer,U. und Hegner, M. (1994) Neue "Augen" für Biologen, UniNova 72/94, 38-40

1993

  • Hegner, M., Wagner, P. and Semenza, G. * (1993) Ultralarge atomically flat template-stripped Au surfaces for scanning probe microscopy Surface Science, 291, 39-46. pdf
  • Hegner, M., Wagner, P. and Semenza, G. * (1993) Immobilizing DNA on gold via thiol modification for atomic force microscopy imaging in buffer solutions FEBS Letters, 336, 452-456. pdf

1992

  • Hegner, M., Kieckebusch-Gück A. v., Falchetto, R., James, P., Semenza, G. and Mantei, N.* (1992) Single amino acid substitutions can convert the uncleaved signal-anchor of sucrase-isomaltase to a cleaved signal sequence, J. Biol. Chem., 267, 16928-16933. pdf


Pageviews: Web Counter